Product Details:
Payment & Shipping Terms:
|
Ultimate Pressure: | CF:6×10-8 ISO-K:6×10-7Pa | Flange: | DN160 CF/ISO-K |
---|---|---|---|
Cooling: | Air | Recommended Forevacuum Pressure: | 100Pa |
High Light: | mini pumping station,vacuum pump station |
Pump station FJ-700F, Air cooling with RVP-6 and ZDF-11A2
FJ-700 F standard Turbo Molecular Pump Unit is an cleaning equipment to obtain high vacuum.
Such equipment is a vacuum obtaining system adopting the principle of vacuum, and consists of mechanical pump and molecular pump. It is featured by quick starting, high vacuum, few oil pollution, easy operation and etc and widely used in the fields of surface analysis, accelerator technology, plasma technology, electric vacuum device manufacturing and other vacuum areas. The equipment is specifically composed of non-standard frame,mechanical pump and pipelines, electrical control systems, water
cooling protection control and etc.
Configuration:
Name | Number |
FF-160/700F molecular pump and power supply | 1 |
RVP-6 mechanical pump | 1 |
Frame | 1 |
Control power supply | 1 |
ZDF-11A2 combination vacuum gauge | 1 |
Other attachments |
Features:
1. Quick starting
2. High vacuum
3. Less oil pollution
4. Easy operation
5. Wide application
Specifications:
Unit | FJ-700 | |
Flange(In) | DN160 CF | |
DN160 ISO-K | ||
Flange(Out) | ISO-KF | DN40 |
Pumping Speed | l/s | N2:700 |
He:580 | ||
H2:260 | ||
Ar:680 | ||
Compression Ratio | N2:109 | |
He:107 | ||
H2:106 | ||
Ar:109 | ||
Ultimate Pressure | Pa | CF:6×10-8 |
ISO-K:6×10-7 | ||
recommended forevacuum pressure | Pa | 100 |
forevacuum pump | RVP-6( default ) | |
Cooling Type,Standard |
Air |
|
Cooling Water Consumpyion | L/min | >1 |
Cooling Water Temperature | ℃ | ≤25 |
Input voltage/ frequency | V/Hz | 380±20/50 |
Environment temperature (℃) | Water cooling | 5℃-40℃ |
mounting position | Vertical | |
Controller Model | FD-ⅡB/TCDP-Ⅱ | |
L*W*H | mm | 550×690×850(water) |
Weight | kg | 135 |
Maintenance:
1. Routine maintenance:
During the daily use of the equipment, pay attention to observing the vacuum pump’s oil level and the pump oil color; if the oil is lacking, supply it in time. If the pump oil color is abnormal, change it in time.
2. Maintenance during the running:
During running of the equipment, pay attention to maintain the pumped vacuum chamber clean, so as to avoid the debris entering into the vacuum chamber and cause the damage of the equipment.
Contact Person: sales
Tel: +8613810212935